Thank you. },
Thanks. Again, flow rate is good but it doesnt make the change in pressure like it should when switching to sweeper. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. so.it shut off again. One of the tads were not in the slot. Has been running great. The water is probably not related, but yeah, may be a loose hose or if not, then likely a bad shaft seal. Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. Do you have any advice? Automatic reset is 60 minutes. Open the door and inspect for debris with a mirror and flashlight. Then, take a look at the capacitor, located at 9 oclock. Am I doing something simply stupid, or should I call the pool people tomorrow? Check in morning and basket is half full with water trickling in basket. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). I removed the capacitor and had it tested at a local pool store and they told me it was fine. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. On page 30 of the Aquarite troubleshooting guide, it goes into depth about troubleshooting that rectifier. I just dont know when it was purchased or how to even find out from the previous owners. It now trips the breaker whenever i try to turn it back on. Copyright 2022 In The Swim. Air can also be drawn into the pump from leaky suction side valves (skimmer or main drain). Replaced breaker still nothing. Make sure you. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. Could also be low water level in the pool, or a stuck skimmer weir, blocking water flow. I keep reading that it could be a seal. . It can also happen when voltage is incorrect (too high or too low), or when wires are shorting out, or in some cases, very hot weather and direct sunshine and other nearby sources of heat. 2. pump lid I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. We have a c48l2n134b3 pump. Quite a criticism for something costing 33bn-plus. The pump is pretty hot. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. If you can grab the bolt head underneath the pad with pliers, that could help, otherwise you can cut the bolts off using a reciprocating saw with a metal blade. Any thoughts? The pump never turns off but it should pull the water through constantly. If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. If control input data is corrupts, the heater will shut down and lockout. I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. it runs about 30 minutes and trips the breaker. In the meantime, could you send me a link for the capacitor that I need? (GFI 240V 20amp) See below for more detail. Are I on the right track? Should be under warranty I would call the PB back out to troubleshoot it, or if not possible, contact the manufacturer of the control system. Thats not right if it is a 3-phase motor, perhaps the wires are switched, but for a regular hayward pump (residential) 3-phase power would be very rare. Hey John This year I have developed a leak under the pump housing I believe. It could also be a loose switch in the back of the motor. Also, using Teflon pool lube on the pump lid oring should help. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. I had an old hayward 1.5 hp power flo matrix 2 speed pump. Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. Power Pole Distribution Block, Now I am looking to replace the old filter. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. Using a circuit tester, I determined that the timer and the inline switch has power. ), is power, verify that power is leaving the timer and arriving at the motor. We would like to show you a description here but the site wont allow us. I tried to restart them & only got a low buzzing type noice. which can clog the tiny gears, or wire issues, burned spots or chewed wires (ants). If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). If outlet is melted, youll need a replacement. Not sure power goes to the pump. The HS (High Sense (water temperature) will appear if the water sensor is reading above 105 OR if the sensor detects an increase of more than 6 with-in 60 seconds. Other problems that could cause this could include a (very) clogged impeller, something actually preventing the shaft from turning or it could be a bad capacitor, a black cylinder in the rear of the motor. Entire pump system with pump basket and housing. Pool Supplies Near Me Open Now, Help. 3 things are key, 1. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. "url": "https://blog.intheswim.com/"
But just like any sort of equipment, even the most well-made products sometimes need repairs. We knows its not electrical. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. Hi the strainer housing must need to be tightened up. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Additional causes for low water flow in your pump are debris build-up or dirty equipment. For more in depth troubleshooting or if you need help discerning which one to replace first, we recommend calling Hayward directly. replacement. Also that some circuit breakers used can create such noise as to cause problems with this error message. Lube should not be the issue with the leak, not required. Are you getting 230V (207v 253V) at the pump? 3. loose pipe coming into pump, drawing air around fitting threads If there is input power, the fuse may have blown. Nothing your husband did, hes safe to come out of the doghouse, lol. When I switch to waste or backwash, the suction is restored to full power and the flow is at full strength. I would try a couple of turns of Teflon tape on the threads to create a better seal. This is Poolside Chat where every week we answer your questions on how to fix and maintain your swimming pool. He did notice that there was de inside of the filter grids so prior to putting it back together we completely flushed each of the grids making sure to get all the de out from inside of them. You could also use a Hayward 24 sand filter, item E3324. I checked the 20A fuse and it is good. You will have a choice of replacing the bearings or having a local electric motor shop do it, or replace the entire motor, or the entire pump. If this is an ABG pool, check the skimmer hose and adapter fittings. Hi Tammy, could be many things. There should be no continuity. The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. The display shows nothing as if it is not getting power. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. Your chlorine generator is still producing chlorine at the moment, which is a good thing. The filter caterige is brand new too. However it doesnt turn on. Automatic restart 2 min after error is corrected. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
Usually however, a howling or moaning sound from the pool heater, is low water flow. One of those areas can be sealed up to stop the leak. Thanks. After just a few minutes the flow slows down to almost nothing. I spent 1 hour one one bolt alone. 2. The capacitor is like the battery in your car its needed to help get the pump up to speed (3200 RPMs) fast. 58 amps! The AquaTrol is an above ground pool salt chlorine generator that can chlorinate a pool up to 18,000 gallons. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Not the power leads, but other connecting wires from the terminal board to the switch, to the cap? Or do I have a friction issue in the impeller? Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. Hi Larry, valid question. If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. I have replaced my existing super pump with new one. If thats not it pull the motor out of the pump, and test the motor briefly to see if the sound continues, if so I would expect bad bearings, or perhaps a loose shim washer, inside the motor, under the front or rear end bell. Step 2: Did you properly install your switch? 3 No air bubbles on my returns when not vacuuming The outlet has been replaced and the issue is still happening. Put things back together and still have error. An electric motor shop local to you could test them, perhaps for free or low cost. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Its a 16-14 250 amp connection. It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). You have both filter pump and polaris pump on one timer? Whats the problem. Every time I vacuum my pool and then back wash and rinse. We also a sense and dispense for pool chemistry that sometimes has a ph feeder timeout error code.could this have something to do with the pool pump running off the scheduled time? Hi there. Hi Andy, good question thanks Motor will start on low, but not on high. I will re-check all the wiring. 6. I have no display showing. 6. Secondly, it could be an air leak after the pump, around the filter, causing air to leak in when the pump shuts off (would be a water leak when the pump is on), which causes the water to drain out of the pump and back to the pool. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. vacuum on waste last night. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. Normally when the device is turned off and we do get the lid off, water runs back into the basket from the filter, it almost sounds like its creating almost a vapor lock, like in an engine. It's a little over 3 years old and the cell checked out fine. You need to use a K-1766 salt test kit or a calibrated meter. This is actually the second motor in 6 months. The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. Thanks A. Ray Davis I even removed the outflow from the filter and ran that directly in case the filter was clogged. Turned it off tho clear the skimmer basket.. water level is correct. Big mistake! Then recharge with a good dose of DE powder. Please help. are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) The pump has been fine since installed, we started up he pool about 30 days ago no issues. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. I hadnt run my pumps in a couple of weeks. I couldnt believe it..after two weeks and a new pump! If your salt cell is plugged into an GFI outlet, make sure that the test button is not popped, or tripped. Is this a 2-speed pump, or variable speed pump? Check the motor vent holes, (bottom front) to be sure they are not clogged. The last one lasted about 3 years. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. "url": "https://intheswim.com/",
Hi Leah, good question, and I understand. Pumps, Learn About Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. Tim, all I can think of is maybe the pump is not self-priming pump? The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. Find these plugs and remove them by loosening the wingnut and wiggling it out. Contact a professional for further assistance. There may be some stray voltage running around the system, on the bonding wire. "@type": "Organization",
was spinning counter clockwise. This is weird, no? what do you think the hum could be? I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Used Cozzia Massage Chair, If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. If you have an electric shop nearby, they could test it, but if its around 10 yrs old, you may assume its dead. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? Any advice?? A closed valve, or plugs in the pool wall? I am a new pool owner and first Hayward pump. It may not display this or other websites correctly. Then, I tried plugged the pump into another power outlet and it still does not work. hayward salt cell plumbing diagram blue essence 20 manual hayward aquarite troubleshooting guidehayward salt system troubleshooting aqua rite diagnostic codes Blue essence salt chlorine generator owner's manual Salt Chlorinator Cell Replacement, Salt Water System Parts, Pool Light, Pool Alarm, Pool. HELP!!! second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. Went to clean the pool filter a few days later and now when turning on the pump it made a loud grinding noise. All of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have 25 The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Its likely good advice you are getting. You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. I took apart the impeller and didnt see anything that could cause a problem. Hi Tim, when the windings in a motor are shorted, the motor is pretty much dead, they arent rewound anymore, like in the old days. If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). Im having a problem with my super pump. Now it wont flip back on but it is still raining hard. Hi there, I have a 2-speed (hi and low) Hayward pump. Not that I can think of, but something seems to be aerating your water? I was just wondering if you thought that could be the issue unless it could be something else. Hi Larry, When DE is coming back into the pool, its usually: When I turn on my pump it runs normal for 5 seconds thank it winds down then reverts back to normal speed. Buen suerte! Follow disassembly/assembly procedures (pages 32 -37). Ive replace the salt cell, circuit board, and flow switch and my Acurite is still reading high salt. Thanks, Hello , This is an inactive thread. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Click Here to View Replacement Aquarite Parts The rooms are equipped with a [] | Egypt Travel & Tourism Agency. I have to say Ive never touched it before during almost 6-years of normal operation. I assume from your post that there are 2 possibilities 1) bad capacitor (I assume I can spot it visually) or 2) frozen shaft or propeller (how do I spot it and fix it? Almost like it was revving. It can also be a bad outlet, and if older than 20 yrs, it could be the breaker too. Hi Carrie, sounds like an air leak, which is air being sucked into the pump, from somewhere in Front of the impeller, For more info, see page 36 of the Hayward heater owners manual. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Maybe sand it down briefly and WD-40 it after it comes off. Flipping the switch makes nothing happen. Yes, you can briefly test motors, for a few seconds without water, no problem. Air leaks or other obstructions BEFORE the pump (including a clogged impeller), will cause lower than normal filter pressure. Hi "author": {
Is the wire size correct? So, it could be a problem with the cord, or the connection on the other end of the cord, likely if the motor is making no noise at all. Rob, the air leak is coming from the pump, or before the pump. I would inspect it for corrosion, wire tightness, water damage or insect damage. Hi James, for a two speed motor, I would suggest the run capacitor, but not sure if the VS motor has one? JavaScript is disabled. 1. What do you suggest? Corrosion inside the plug or socket. Is that a reason to replace impeller? Wait for the number to. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. Whats that part called in case I do break it? I changed my sand a few weeks and tested it and it worked fine. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. "caption": "In The Swim Blog"
I checked impeller and seems to be spInning freely with no debris. Water Features, View All I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping Breakers do wear out, especially if used often as the pump switch. I replaced the impeller ring and noticed it Is the motor still good. Hope thats not the case. The new pump then starts to overheat and it shuts off. Overheating pumps are usually DOA, in my experience, but there may be hope. Check it out, it could start a fire! Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? I have a Hayward Super Pump VS 2 hrs old. Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. Pump shutoff during 24 hours of pouring rain. 1. Im being advised by an electrician that my Hayward pump has a dead short in it. After resetting the switch 3 times yesterday,the pump is finally staying on. Still same though nothing being sucked through basket and minor trickle back out into pool. Do you have a video clip to show how to replace it? It has the switch at the bottom to turn on along with the built in timer. What does your water temp say? Just purchased a Hayward SP32002VSP. SOme pumps have an open bracket where you can see the shaft, but not Hayward. You are using an out of date browser. My pool suppoier said 50lb but the info on the description of the filter on the site where purchased says 100 lbs. Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. Sparking can also come directly from a short in the windings of the motor. "height": "219",
One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. Do I need to do something else to get it to prime faster? Check that they are tight and havent come loose. Hi Wade, check the switches in the rear of the motor, the stationary switch, located at 6 oclock, and the centrifugal switch, located dead center. I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. The pump itself works great. The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself.